Ataque localizado de metales. Parte l
Cargando...
Archivos
Fecha
Autores
Título de la revista
ISSN de la revista
Título del volumen
Editor
Comisión Nacional de Energía Atómica; Argentina
Organización de los Estados Americanos
Organización de los Estados Americanos
Resumen
The anodic behaviour of puré Al and somc specially prepared Al-Cu alloys has been studied to check the mechanism of intergranular corrosion of aged Al-4%Cu. A clear relationship between pitting and intergranular corrosion has been found. Intergranular corrosion only occurs in the presence of certain anions, and over a narrow range of potentials. Difference in pitting potentials, rather than difference in electrode potentials, is the main factor in producing intergranular corrosion of Al-4%Cu. The conditions of hcat treatment, solution composition, and potential, at which intergranular corrosion appears, have been established.