Logotipo del repositorio

Corrosion monitoring of post-tensioned strands at the Piedra del Aguila spillway

cnea.tipodocumentoARTÍCULO CIENTÍFICO
dc.contributor.authorBurkart, Arturo L.
dc.contributor.authorDuffó, Gustavo Sergio
dc.contributor.authorCastro, P.
dc.date.accessioned2025-12-11T23:28:52Z
dc.date.available2025-12-11T23:28:52Z
dc.date.issued2014-12
dc.description.abstractThe Piedra del Aguila project in Argentina is a concrete gravity dam constructed in the 1980s,on the Limay river. The dam includes a spill way channel controlled by four gates. The spillway structure includes several post-tensioned systems installed in the concrete piers. These systems do not meet the cable protection standards of modern methods, which provide two barriers against corrosion and can be monitored. In 2004, several leaks were detected that could have reached the steel tendons. Because of this, an innovative programme was developed toas certain the integrity and remaining life of thesteel strands.This paper presents a summary of the activities performed and the instrumentation installed at Piedra del Aguila to assist with the long-term monitoring of the dam.
dc.description.institutionalaffiliationFil: Burkart, Arturo L.. Comisión Nacional de Energía Atómica; Argentina
dc.description.institutionalaffiliationFil: Duffó, Gustavo Sergio. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Unidad de Actividad de Materiales (CAC); Argentina. Universidad Nacional de San Martín; Argentina
dc.description.institutionalaffiliationFil: Castro, P.. Hidroeléctrica Piedra del Aguila S.a.; Argentina
dc.identifier.issn1352-2523
dc.identifier.urihttps://nuclea.cnea.gob.ar/handle/20.500.12553/8383
dc.publisherHydropower & Dams, Aqua-Media International Ltd
dc.relationinfo:eu-repo/semantics/reference/hdl/11336/47744
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://www.hydropower-dams.com/article_detail.php?c_id=208&aid=3289
dc.rights.licenseinfo:eu-repo/semantics/openAccess
dc.rights.licensehttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subjectCorrosion
dc.subjectSteel
dc.subjectSensors
dc.subjectHydropower Dam
dc.subjectOtras Ingenierías y Tecnologías
dc.subjectOtras Ingenierías y Tecnologías
dc.subjectINGENIERÍAS Y TECNOLOGÍAS
dc.titleCorrosion monitoring of post-tensioned strands at the Piedra del Aguila spillway
dc.typeARTÍCULO
dc.type.versionVersión publicada

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
file_992_0.pdf
Tamaño:
5.16 MB
Formato:
Adobe Portable Document Format