Two-phase flow in the localized boiling field adjacent to a heated wall
| cnea.tipodocumento | INFORME TÉCNICO | |
| dc.contributor.author | Bonetto, Fabián José | |
| dc.contributor.author | Clausse, Alejandro | |
| dc.contributor.author | Converti, José | |
| dc.contributor.cneaproductor | Comisión Nacional de Energía Atómica; Argentina. Centro Atómico Bariloche | |
| dc.date.accessioned | 2025-09-03T14:58:54Z | |
| dc.date.available | 2025-09-03T14:58:54Z | |
| dc.date.issued | s/f | |
| dc.description.abstract | An experiment performed in a small horizontal heater immersed in refrigerant FC-72 is presented. The spatial distribution of the vapor is measured using a hot wire anemometer located over the heater for different heat power inputs. The experimental data is analyzed using a probabilistic model to obtain information about the void fraction bubble size and vapor velocity. | |
| dc.description.institutionalaffiliation | Fil: Bonetto, Fabián José Comisión Nacional de Energía Atómica; Argentina | |
| dc.description.institutionalaffiliation | Clausse, Alejandro Comisión Nacional de Energía Atómica; Argentina | |
| dc.description.institutionalaffiliation | Converti, José Comisión Nacional de Energía Atómica; Argentina | |
| dc.format.extent | 26 p. | |
| dc.format.extent | application/pdf | |
| dc.identifier.uri | https://nuclea.cnea.gob.ar/handle/20.500.12553/7159 | |
| dc.language.ISO639-3 | eng | |
| dc.publisher | Comisión Nacional de Energía Atómica; Argentina | |
| dc.rights.accesslevel | info:eu-repo/semantics/openAccess | |
| dc.rights.license | Creative Commons Atribución-NoComercial-CompartirIgual 4.0 Internacional | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | |
| dc.subject.inis | ENSAYOS | |
| dc.subject.inis | VAPOR | |
| dc.subject.inis | ANEMÓMETROS | |
| dc.subject.inis | BURBUJAS | |
| dc.subject.inis | VISUALIZACIÓN DE FLUJO | |
| dc.subject.inis | TESTING | |
| dc.subject.inis | STEAM | |
| dc.subject.inis | ANEMOMETERS | |
| dc.subject.inis | BUBBLES | |
| dc.subject.inis | FLOW VISUALIZATION | |
| dc.title | Two-phase flow in the localized boiling field adjacent to a heated wall | |
| dc.type | info:eu-repo/semantics/report | |
| dc.type | info:ar-repo/semantics/informe técnico | |
| dc.type.version | info:eu-repo/semantics/publishedVersion |