dc.description.abstractThe dynamic response to different seismic inputs of an isolated structure disposed on a sliding layer and connected to the ground with a superelastic NiTi device was analyzed. The device allows wires of NiTi to be mechanically cycled by supporting externally applied tension/ compression forces exploiting both dissipative and self-centering capabilities associated with superelasticity. Simulations were carried out modifying the wires length and the structural mass. Both parameters were varied over two orders of magnitude with the aim of evaluating the type of response, the mitigation level that can be accomplished and the combination of parameters resulting in an optimal response. Results indicate that the proposed device is suitable for seismic protection of isolated structures and it is demonstrated that the protective action is more related with the restraining and self-centering properties of the NiTi superelastic wires than with its damping capacity.
dc.description.institutionalaffiliationFil: Soul, Hugo Ramon. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche. División Metales; Argentina
dc.description.institutionalaffiliationFil: Yawny, Alejandro Andres. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche. División Metales; Argentina
dc.identifier.issn0964-1726
dc.identifier.urihttps://nuclea.cnea.gob.ar/handle/20.500.12553/7575
dc.publisherIOP Publishing
dc.relationinfo:eu-repo/semantics/reference/hdl/11336/57879
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://dx.doi.org/10.1088/1361-665X/aa7caf
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://iopscience.iop.org/article/10.1088/1361-665X/aa7caf/meta
dc.rights.licenseinfo:eu-repo/semantics/openAccess
dc.rights.licensehttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subjectDynamical Response
dc.subjectPerformance Analysis
dc.subjectSuperelastic Device
dc.titleApplicability of superelastic materials in seismic protection systems: A parametric study of performance in isolation of structures
dc.typeARTÍCULO
dc.type.versionVersión publicada

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
file_1033_0.pdf
Tamaño:
3.68 MB
Formato:
Adobe Portable Document Format